Guide
Septic tank general binding rules and regulations
If your home is not on mains drains, you may have a septic tank. This guide sets out the rules on emptying, discharge and siting.

What the general binding rules are
The general binding rules are national rules for small sewage systems that discharge to the ground or to a surface water, such as a river or stream. In England, the Environment Agency says you do not need a permit if you meet all the general binding rules that apply to you.
These notes apply to England, with Wales covered below.
Emptying
In England, the Environment Agency says sludge in a septic tank or small sewage treatment plant should be removed before the tank reaches its maximum capacity, at least once a year or as the manufacturer's instructions say. It says the company that takes the sludge away must be a registered waste carrier. You can ask the company or the tanker driver for a copy of the waste carrier certificate.
Cost guides put emptying a septic tank at £150 to £300 for most homes.
Discharge to a river or stream
In England, the Environment Agency says that if a septic tank discharges directly to a surface water such as a river or stream, you should act as soon as possible, usually within about 12 months. Its options are to connect to a public foul sewer, replace the tank with a small sewage treatment plant, or install a drainage field.
Siting a drainage field
Approved Document H, the official guidance on the Building Regulations for drainage, says a drainage field or mound should be at least 10 metres from any watercourse, at least 50 metres from a groundwater supply, and at least 15 metres from any building.
In England, the Planning Portal says the Building Regulations also apply to all non-mains foul drainage, including septic tank outlets and drainage fields.
Wales
Natural Resources Wales says a septic tank should be emptied every 12 to 24 months by a registered contractor, and a small sewage (package) treatment plant should be serviced every 12 months. It says owners should register a system with it, usually as a one-off and free if conditions are met.
Common questions
How often should a septic tank be emptied?
In England, the Environment Agency says at least once a year or as the manufacturer says. Natural Resources Wales says every 12 to 24 months for a septic tank.
How do I check a tanker firm is allowed to take the waste?
In England, the Environment Agency says it must be a registered waste carrier, and you can ask for a copy of the certificate.
Do I need to register my tank in Wales?
Natural Resources Wales says owners of a building not connected to a mains sewer should register.